Hydrox MnO2 Media 0.5-1.5 mm

Description

Hydrox removes iron, hydrogen sulfide, and manganese. It continues to perform even when other iron-reduction media fail, thanks to its resistance to O₂, Cl₂, and ozone. Because Hydrox requires a smaller quantity to achieve the same flow rates as other media types, media costs are reduced. It also offers the highest flow rate among standard iron-removal media and needs no chemicals for regeneration.

Since less Hydrox is typically needed, smaller tanks can be used to achieve the same flow capacity, further lowering system costs. In addition, using air filter tanks increases backwash efficiency by providing greater lift, conserving water, and improving the removal of particles such as iron or sulfur that have been captured by the filter.

Features

pH Range

6.8 - 9.0 for iron removal
7.8 - 9.0 for manganese removal

Packaging

25kg (15L)

Bed Depth

20" minimum

Recommended Service Flow Rate

8 - 24 m/h

Recommended Backwash Flow Rate

35 - 55 m/h

Freeboard

30 - 50% of bed depth

Bulk Density

1,5 kg/l +- 0.1kg/l

General Technical Data

Recommended Service Flow Rate varies according to inlet iron quantity.